User`s manual
14
TYPICAL SETTINGS
Set Point : 59°F to 104°F / Factory set at 84°F
Filter Cycle Duration: 0 to 24 hrs / Factory set at 24 hrs
Max Set Point: 59°F to 104°F / Factory set at 104°F
Purge Cycle Frequency: 1 to 4 times a day / Factory set at 4
KEYPAD DOESN’T SEEM TO WORK
If a keypad doesn’t seem to work:
• Verify keypad connections.
• Replace keypad if problem is corrected.
• Replace in.xe if problem is not corrected.
in.xe UL/CSA electrical specifications:
Input rating: 120/240 VAC
(2-phase required, with neutral) 48 A maximum, 60Hz.
Software limited to 24A. Install on a 30A GFCI circuit.
Output ratings:
Output Voltage Current Typical Device
Out 1 120/240V 17FLA Pump 1
Out 3 120/240V 0.8 A Circulation
Pump/Blower
Out 4 120/240V 1 A Ozone Generator
Out 5 120/240V 5 A Audio/Video device
L1 Light, 12VAC, 0.1 A
CO Communications port *
C1 Top side controller *
*CO: Comm.connector (in.stik).
heat.wav ratings:
Voltage: 120/240VAC
Current: 17A resistive (4 kW heater at 240V)
Frequency: 50 / 60 Hz
heat.wav heater flow rate:
Minimum of 18 GPM is required
Important:
• All low voltage accessories use + 5Vdc and/or + 12 Vdc.
• All low voltage accessories combined:
150 mA max, on + 12 Vdc.
GENERAL SPECIFICATIONS:
Environmental:
Operating temperature: -20°C (-4°F) to 60°C (140°F)
Storage temperature: -25°C (-13°F) to 85°C (185°F)
Humidity: up to 85% RH, non condensing
IPx5 level of waterproofing is conditional on 3 items:
• Both front covers (heater and input wiring) are closed and
screwed shut.
• A waterproof strain-relief/bushing is used for the cable entry
into the pack.
• Any unused in.link connections (HC, LC, or low voltage) is
plugged with the appropriate blank plug.
Mechanical:
Weight: 4.76 kg (10.5 lbs)
Dimensions (W x H x D):
Chassis: 441.5mm x 298.5mm x 129mm
(17.38" x 11.75" x 5.1")
UL/CSA Standards:
UL 1563 Fifth Ed.
File: E182156
CSA No. 22.2 - 218.1-M89.
TUV Standards:
EN/IEC 60335 - 2 - 60
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3
The in.xe is lab tested to IPx5 enclosure protection levels.
in.k200 full-function keypad
The Quick Reference Card provides a quick overview of your
spa’s main functions and the operations accessible with your dig-
ital control pad.
Spa Functions
Up/Down Keys
Use Up or Down key to set
desired water temperature.
The temperature setting
will be displayed for 5 seconds
to confirm your new selection.
The “Set Point” icon indicates that the display
shows the desired temperature, NOT the current
water temperature!
98