User manual
UP.l1
UP.l1 HYS.U + 
UP.l1 HYS.U - 
LO.l1
LO.l1 HYS.L + 
LO.l1 HYS.L - 
Out
Out
dly.U
A.out n.c. = 
A.out n.o. = 
dly.U
dly.ldly.l
Input
t
t
t
Dimensions
 Note : 
71,5mm
29,5mm
2/5
A
-A
0
A
0
A
0
A
-A
A
0
A
0
A
-A
0
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
0
T
3T/2
T/2
2T
T
3T/2
T/2
2T
d
d
T
2T
0.308 A
0.386 A
0.000
A
0.000
A
d
T
d
T
A
A
d
T
A
d
T
2
2
0.000
1
2
A
1
2
A
2
A
1
2
A
p
1
2
A
1
A
p
2
A
1
2
A
1
2
A
1
3
A
1
3
A
1
 ac
Ac.dc
dc
(rms)
To remove the device from panel: 
-  While pushing the the flush-
mounting clamp in direction 1,pull out
it in direction 2.
1) Panel thickness should be 
7mm.
2) If there is no 60mm free space at the back 
side of the device, it would be difficult to 
remove it from the panel. 
 maximum 
Panel cut-out
Connection Diagram
4
5
SUPPLY:
NOTE :
184-253V AC 
50/60Hz 5VA
Line
Neutral
Note: 
Cable Size: 1,5mm²;
230V AC
Supply 
Switch
Fuse 
F 100mA 
250V AC
Fuse should be connected.
1) Mains supply cords shall meet the requirements of 
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power 
supply switch shall bring the identification of the relevant 
instrument and it should be easily accessible by the operator.
4
5
Faz
Nötr
Equipment is protected throughout by 
DOUBLE INSULATION
Holding screw 0.4-0.5Nm.  
Panel
Depth
2
61mm
5mm
Rubber
packing
Flush mounting 
clamp
1
ENDA EPV241A is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of the 
cables that are connected to the device must be free of electrical power. The device must be protected 
against inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is 
not exceeded. The cables should not be close to the power cables or components. 
35mm
77mm
SETSET
 EPV 241A
ENDA
OUT AC DC ACDC
V
CAT II
+ 
1 2 3 4 5 6
7 8 9
10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPV241A-R-230VAC-RSI
PROGRAMMABLE 
AC/DC VOLTMETER
11
12
 OUTPUT
 250V AC 8A 
RESISTIVE LOAD
 COM.
 B
 A
8 680407 704934
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+ 
Max. 500V
 AC / DC 
 Max. 50V
 AC / DC 
CAT II
+ 
1 2 3 4 5 6
7 8 9
10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPV241A-230VAC
PROGRAMMABLE 
AC/DC VOLTMETER
11
12
8 680407 704903
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+ 
Max. 500V
 AC / DC 
 Max. 50V
 AC / DC 
CAT II
+ 
1 2 3 4 5 6
7 8 9
10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPV241A-230VAC-RSI
PROGRAMMABLE 
AC/DC VOLTMETER
11
12
 COM.
 B
 A
8 680407 704910
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+ 
Max. 500V
 AC / DC 
 Max. 50V
 AC / DC 
CAT II
+ 
1 2 3 4 5 6
7 8 9
10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPV241A-R-230VAC
PROGRAMMABLE 
AC/DC VOLTMETER
11
12
 OUTPUT
 250V AC 8A 
RESISTIVE LOAD
8 680407 704927
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+ 
Max. 500V
 AC / DC 
 Max. 50V
 AC / DC 
If C.Inp input type “500” is selected, the measurement terminals 9 and 12 of the terminals must be connected. Otherwise the measurement is done incorrectly. 
If C.ınp input type “50” is selected, the measurement terminals 10 and 11 of the terminals must be connected. Otherwise the measurement is done incorrectly. 
EPV241A-E-02-R-201307