Data Sheet

75mm
84mm
68 mm
+0.7
68 mm
+0.7
mA LED : If input type is selected as 0-20mA or 4-20mA, mA LED lights up.
In "Running Mode", indicates output set value.
In “Programming Mode”, indicates the selected parameter value.
V LED : If input type is selected as 0-1V or 0-10V, V LED lights up.
ALR LED : If alarm output is active, ALR LED lights up. During delay time, LED flashes.
OUT LED : If “OUT” is active, OUT LED lights up. During delay time, LED flashes.
FRONT PANEL
Panel Cut-out
Note :
1) While panel mounting, additional distance required
for connection cables should be considered.
2) Panel thickness should be maximum 10mm.
3) If there is no 90mm free space at back side of the
device, it would be difficult to remove it from the panel.
DIMENSIONS
CONNECTION DIAGRAM
In "Running Mode", indicates the maximum measured value.
Used for incrementing values in "Programming Mode".
In "Running Mode", indicates the minimum measured value.
Used for decrementing values in "Programming Mode".
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply switch shall bring
the identification of the relevant instrument and it should be easily accessible by
the operator.
Note :
12
11
184-253V AC
50/60Hz 7VA
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
In "Running Mode", indicates the alarm set value
Depth
Connection
Cables
Flush mounting
clamp
Gasket
Panel
- Push the flush-mounting clamps in direction
- Pull out the clamps in direction
To removing the device from the panel:
1
2
1
2
72mm
78mm
PROGRAMMABLE INDICATOR
ENDA
EI7041
OSET
SET
MAX
ASET
MIN
mA
V
ALR
OUT
1
2
ENDA EI7041 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The shielding must be grounded on the
instrument side. During an installation, all of the cables that are connected to the device must be free of energy. The device must be protected against
inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded. All input and output lines that are not connected to
the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. The installation and
electrical connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations.
INPUT
GND
230V AC +10% -20%
50/60Hz 7VA
11
12
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7041-230-2R-12-RS
INDICATOR
OUT
AC 250V 8A
RESISTIVE LOAD
+
A
1
2
8
6
8
0
4
0
7
7
1
6
9
2
0
Made In Turkey
AUXILIARY
SUPPLY OUT
12V 50mA
GND
+
ALARM
AC 250V 8A
RESISTIVE LOAD
B
13
14
15
16
17
18
19
20
Holding screw
0.4-0.5Nm.
Equipment is protected
throughout by
DOUBLE INSULATION
2. / 5
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
EI7041-E-28092021
PROGRAMMABLE INDICATOR
ENDA
EI7041
OSET
SET
MAX
ASET
MIN
mA
V
ALR
OUT