Data Sheet
TERMS
4 digits 7 segment yellow LED display
( 2 ),( 3 ),( 4 ),( 5 ) Keypad
( 1 ) Digital display
DIMENSIONS
CONNECTION DIAGRAM
2
1
184-253V AC
50/60Hz 7VA
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
1) Measurement value, measurement unit, the minimum or the maximum measured values are
displayed in the run mode.
Parameter name, parameter value or a user defined unit is displayed in the programming mode.
3) De
Used for making the minimum and the maximum measured values equal in the run mode.
crement or parameter selection key in the programming mode.
2) Increment or parameter selection key in the programming mode.
Used for displaying measurement unit or the max. measured value in the run mode.
4) Used for selecting run and programming modes, displaying
measurement unit or
adjusting parameters,
making the minimum and the maximum measured values equal.
12.5mm
Micro switch
Character height
ENDA EI141isintendedforinstallationincontrolpanels.Makesurethatthedeviceisusedonlyforintendedpurpose.
Duringaninstallation,allofthecablesthatareconnectedtothedevicemustbefreeofenergy. Thedevice
mustbeprotectedagainstinadmissiblehumidity,vibrations,severesoilingandmakesurethattheoperationtemperatureisnotexceeded. All
inputandoutputlinesthatarenotconnectedtothesupplynetworkmustbelaidoutasshieldedandtwistedcables. Thesecablesshouldnotbe
closetothepowercablesorcomponents.
Theshieldingmustbe
groundedontheinstrumentside.
Theinstallationandelectricalconnectionsmustbecarriedonbyaqualifiedstaffandmustbe
accordingtotherelevantlocallyapplicableregulations.
1)MainssupplycordsshallmeettherequirementsofIEC60227orIEC60245.
2)Inaccordancewiththesafetyregulations,thepowersupplyswitchshallbringtheidentificationoftherelevantinstrumentanditshouldbe
easilyaccessiblebytheoperator.
Note:
Holdingscrew
0.4-0.5Nm
Equipmentisprotectedthroughout
byDOUBLEINSULATION.
Panel cut-out
71mm
29mm
Panel
2
1
Pushuptheflush-mounting
clampindirection as
showninthefigureabove.
Then,pullouttheclampin
direction
-
1
-
2.
Forremovingmountingclamps:
Rubber
packing
Flush mounting
clamp
Panel
Flush mounting
clamp
Note:
1)Panelthicknessshouldbemaximum7mm.
2)Ifthereisno60mmfreespaceattheback
sideofthedevice,itwouldbedifficultto
removeitfromthe anel.p
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
EI141 PROGRAMMABLE INDICATOR
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 7VA
INPUT
+
GND
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ENDA INDUSTRIAL ELECTRONICS
24V DC 10%
7VA
±
INPUT
+
GND
EI141-24DC PROGRAMMABLE INDICATOR
-
+
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
EI141-24AC PROGRAMMABLE INDICATOR
ENDA INDUSTRIAL ELECTRONICS
24V AC +10% -20%
50/60Hz 7VA
INPUT
+
GND
2 -E./3EI141
SETSET
EI141
ENDA
PROGRAMMABLE INDICATOR
SETSET
EI141
ENDA
PROGRAMMABLE INDICATOR
35mm
77mm
SN: XXXXXXXXX
EI141-230VAC
PROGRAMMABLE INDICATOR
ENDA INDUSTRIAL ELECTRONICS
1 2 3 4 5 6
7 8 9
10
11 12
2 V AC +10%-20%
50/60Hz 7VA
30
INPUT
+
GND
2
71mm
5mm