Data Sheet
In the current measurement mode input impedance is 5 Therefore, in the current measurement mode, any voltage input
should not be connected to the input terminals. Otherwise, the device will be broken down.
leave out the voltage inputs. Then, change
input type to one of the current measurement modes.
W.
To change the input type from
voltage to a current measurement mode while the device is operating, first,
EI141 must not be used in location where measurement category is II, III or IV.
* 3 x77mm sized.
* 4 digits display.
* Easy to use by front panel keypad.
* Display scale can be adjusted between -1999 and 4000.
* Decimal point can be adjusted between 1. ile 3. digits.
* Measurement unit can be displayed.
* Selectable four different standard input types (0-20mA, 4-20mA, 0-1V, 0-10V)
* User can calibrate the device according to his/her own specified input type.
* Sampling time can be adjusted in four steps.
* Maximum and minimum measurement values are registered.
* The maximum or the minimum values can be hold on the display.
* Current and voltage calibration can be made..
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.
5
Input type
0-1V DC voltage
0-10V DC voltage
0-20mA DC current
4-20mA DC current
Input empedance
Approx. 11k (terminal voltage limits: min. = -2V, max. = 30V)W
Approx. (terminal voltage limits: min. = -2V, max. = 30V)11kW
Approx. 5 (applicable terminal voltage is max. 50mA.)W
Approx. (applicable terminal voltage is max. 50mA.)5W
ENDA EI141 PROGRAMMABLE INDICATOR
ThankyouforchoosingENDA EI141INDICATOR.
Readthisdocumentcarefullybeforeusingthisdevice. Theguaranteewillbeexpiredby
damagingofthedeviceifyoudon'tattendtothedirectionsintheusermanual. Alsowedon't
acceptanycompensationsforpersonalinjury,materialdamageorcapitaldisadvantages.
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
Ambient/storage temperature
Max. relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Rated pollution degree
TECHNICAL SPECIFICATIONS
80 up to 31 decreasing linearly 50 at 40 .% %°C °C
According to EN 60529 Front panel : IP6
Rare panel : IP20
5
Do not use the device in locations subject to corrosive and flammable gases.
Supply
230VAC +10%/-20%, 50/60Hz, 24VAC±10%,50/60Hz or 24Vac/dc (9-30Vdc or 7-24Vac)
Power consumption
Max. 7VA
2.5mm² screw-terminal connections
Wiring
Date retention
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)
EEPROM (Min. 10 years)
EN 61010-1: 2001 (pollution degree 2, overvoltage category II, measurement category I)
ELECTRICAL CHARACTERISTICS
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
W77xH3 xD7 mm5 1
Weight
Approx. 250g (after packing)
Enclosure material
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or must not be used.corrosive materials
0V
± )0,5% (of full scale
0V
± )0,5% (of full scale
0mA
± )0,5% (of full scale
0mA
± )0,5% (of full scale
1.1V
14V
25mA
25mA
Min.
Max.
Measurement range
Measurement accuracy
english
E-mail:info@suran-elektronik.de
Internet:www.suran-elektronik.de
Tel.: +49(0)7451/625617
Fax:+49(0)7451/6250650
SURAN Industrieelektronik
DettingerStr.9/D-72160Horba.N
uptodate:01022014,modificationreservedandcanbechangeanytimepreviousnotice!
1./3EI141-E
SETSET
EI141
ENDA
PROGRAMMABLE INDICATOR
Order Code : EI141-
1
1 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30VDC/7-24V AC