Product Info

E2ES States
E2ES may be in one of three states:
Idle Started Silenced
In the Idle state, no data is being logged and there is no radio activity. The only way to remove
the E2ES from Idle is to manually push the button.
In the Started state, data is being logged in the circular buer and the Radio is functioning. The
only way to stop the E2ES from logging is to issue the Halt command.
In the Silenced state, data is being logged in the circular buer and there is no radio activity.
The only way to go back to Started state is to manually push the button OR the E2ES will revert
to the logging state after X seconds (set when entering Silenced state).
E2ES Commands
Command Format:
uint8 uint8 up to 16 bytes
Endian Command Args
Response Format:
uint8 uint8 up to 507 bytes
DataCommand Error
Commands take an endian value which dictates the endian of the command and the endian of
the response data. The second value is the command type followed by any arguments.
Responses are prefaced by their command type for verification and dispatch. The second value
is the error flag and the remaining bytes are any data returned by the command issued.
Endian Values:
0 = Little, 1 = Big
Commands:
‘I’ = Info
’T’ = Current Temperature
‘R’ = Read Block
‘U’ = Unlock
’S’ = Silence
‘H’ = Halt
‘Q’ = Quell
Errors:
0 = Success
1 = Unknown Command
2 = Bad Permissions
3 = Incorrect Password
4 = Unknown Error
Permission Level:
0 = Level 0
1 = Level 1
States:
0 = Idle
1 = Started
© 2018 End2End Sensors LLC, ALL RIGHTS RESERVED