Specifications
Monitoring and Troubleshooting the SP201-SA Software 7-17
SP201-SA™ Customization and Maintenance Guide
7.2.4.2 The show almrelay Command
This command lists the alarm relays set up on the SP201-SA. (To configure
alarm relays, see Section 2.3.6, The config almrelay Command.)
How to Use the show almrelay Command
1 At the user> prompt, type show almrelay and press Enter.
The alarm relay display for this SP201-SA appears.
ALARM STATUS:
Major
(also called a
red alarm)
Indicates an active major alarm. Major
alarms are Fs errs, carrLos, syncLos,
mfSynLs, ais, and mtais.
Minor
(also called a
yellow alarm)
Indicates an active minor alarm. Minor
alarms are yellow and mf yel.
Aggregate Alarm Status Shows the alarm status for the SP201-SA
(i.e., where there are major and/or minor
alarms on trunks on the SP201-SA).
user> show almrelay
******************************************************************************
************************* ALARM RELAY CONFIGURATION **************************
******************************************************************************
Trunk With Alarm Alarm Propagated to Trunk
1 - 2 - - - - - -
2 - - - - - - - -
3 1 2 - - - - - -
4 - - - - - - - -
******************************************************************************
Alarm Relay Timer = 25 secs
******************************************************************************
user>
Table 7-2. show alarms Parameter Descriptions (2 of 2)
Parameter Description