Specifications
7-16 Chapter 7: Maintenance and Troubleshooting
SP201-SA™ Customization and Maintenance Guide
user> show alarms
******************************************************************************
***************************** TRUNK ALARM STATUS *****************************
******************************************************************************
MF MF
Alarm MF YEL YEL SYNC SYNC CARR FS
Trunk Reporting AIS AIS LOW LOW LOSS LOSS LOSS ERRS MAJOR MINOR
******************************************************************************
1 ENABLED ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
2 ENABLED ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
3 ENABLED ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
4 ENABLED ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
******************************************************************************
AGGREGATE ALARM STATUS: ---- ----
******************************************************************************
user>
Table 7-2. show alarms Parameter Descriptions (1 of 2)
Parameter Description
Alarm Reporting Indicates whether the trunk’s alarms are
enabled.
ais Indicates whether the alarm indication
signal alarm is activated.
mf ais Indicates whether the timeslot 16
multiframe (if in use) alarm indication
signal is activated.
yellow Indicates whether a remote alarm is
activated.
mf yellow Indicates whether the timeslot 16 (if in use)
remote alarm is activated.
sync Loss Indicates whether a synchronization loss
alarm is activated.
mf Sync Loss Indicates whether a timeslot 16 (if in use)
synchronization loss alarm is activated.
carr Loss Indicates whether carrier loss is on (the
carrier signal has been lost) or off (the
carrier signal is operational).
Fs errs Indicates the presence of F-bit errors. (Not
currently supported.)