Specifications

Monitoring and Troubleshooting the SP201-SA Software 7-15
SP201-SA™ Customization and Maintenance Guide
7.2.4.1 The show alarms Command
You use the show alarms command to view detailed information about the
trunk alarms on the SP201-SA. (To set alarms up, see Section 2.3.5, The config
alarms Command.)
How to Use the show alarms Command
1 At the user> prompt, type show alarms and press Enter.
Information similar to the following is displayed. Empty entries
(dashes) indicate that there is no alarm. Asterisks indicate an alarm.
Table 7-2 describes the parameters displayed for the show alarms
command.
user> show
*** SHOW COMMAND HELP ***
banner - Display application banner
buffers - Display the size of message buffer pools
clocks - Display current clock source for framing
connection - Display CIC/timeslot/peer timeslot relationships
events - Display list of the statemachine Events and States
framers - Display the configuration & status of the trunk (span) framers
hardware - Display hardware configuration information
states - Display the DTMF and Q767 statemachine states for all channels
stats - Display card reset statistics
template - Display the IAM & ACM template number configured for all channels
timeslots - Display timeslot connectivity and data translation in effect
trace - Display tracechan status
trunks - Display trunk (span) framing, protocol & signaling link
information
version - Display application and boot monitor version information