User guide

C-32
Compile-Time Options
Options for Specifying Delays
+allmtm
Specifies enabling the simv executable for the +mindelays,
+typdelays, or +maxdelays options at runtime, instead of at
compile-time, to specify which of the minimum, typical, or
maximum delay values to use during simulation from min:typ:max
delay value triplets in module path delays and timing delays. This
option is also used for compiling SDF files.
This option does not work for min:typ:max delay value triplets in
other delay specification in your source code. Do not use this
option with the +maxdelays, +mindelays, or +typdelays
compile-time options. For more information, see “Specifying
Min:Typ:Max Delays at Runtime” on page 13-38.
+charge_decay
Enables charge decay in trireg nets. Charge decay will not work
if you connect the trireg to a transistor (bidirectional pass)
switch such as tran, rtran, tranif1, or rtranif0.
+delay_mode_path
For modules that contain specify blocks, ignores the delay
specifications on all gates and switches and uses only the module
path delays and the delay specifications on continuous
assignments.
+delay_mode_zero
Changes all the delay specifications on all gates, switches, and
continuous assignments to zero and changes all module path
delays in specify blocks to zero.
+delay_mode_unit
Ignores the module path delays in specify blocks and changes all
the delay specifications on all gates, switches, and continuous
assignments to the shortest time precision argument of all the