Telnet Connection to System Controller
Telnet Connection to System Controller
Using the Hyperterminial (or equivalent) utility program and an Ethernet
connection you can connect to an Encore System Controller (SCB) via
Ethernet. Simply enter the IP address of the SCB. The SCB must be opera
-
tional at the network level, and resetting the SCB drops the connection.
Serial Connection Settings for Encore System Controller
Using the Hyperterminial (or equivalent) utility program and a serial cable
with the appropriate RJ45 adapter, you can connect to an Encore System
Controller for diagnostic or maintenance operations. This type of connec
-
tion allows lower level diagnostics, including the reporting of reset activity.
Use the following settings:
SNMP Monitoring
Encore supports the Simple Network Management Protocol (SNMP) for
monitoring the Encore System Controller.
Note Customers using the Thomson Grass Valley NetCentral application receive
the required Management Information Bases (MIBs) with the NetCentral soft
-
ware. Customers using a Third Party SNMP Manager should contact Cus-
tomer Service for instructions on obtaining MIBs.
SNMP messages originating from Thomson Grass Valley equipment
conform to the SNMPv1 protocol (IETF RFC 1157) and SNMPv2c. These
messages can also be trapped by other SNMP management stations.
Table 18. Encore SCB Serial Connection Settings
Baud Data Bits Parity Stop Bits Flow Control
9600 8 None 1 None