Service manual
Encore — Installation and Service Manual 57
Serial Cabling RS-422/485
Figure 32. COM 2 RS-422/485 Cabling New Encore Frame 6101000xx
See Figure 33 for a cabling example using Encore Control Frame 6100884xx
and two VTRs. A custom crossover is required, either using an available
adapter cable or by crossing the RJ-45/9 Pin D connector (see
RJ-45 to 9-Pin
D Adaptor Pinouts (RS-422/486) on page 66). Do not have both crossover.
Figure 33. COM 2 RS-422/485 Cabling Original Encore Frame 6100884xx
Ports 1 to 8 RS-422/485
Sixteen of the RJ-45 Connectors on the back of the Encore frame are labeled
SIO. Ports labeled 1 (J35) to 8 (J42) are controlled by the SIO ISA Mezzanine
on the System Controller in slot 1. Ports labeled
1 (J43) to 8 (50) are con-
trolled by the SIO ISA Mezzanine on the System Controller in slot 2.
Encore System Controller Frame
8103_04_64r1
RJ-45
Male
RJ-45 Female to
9-Pin D Female Adaptor
RJ-45
Male
RJ-45 Female to
9-Pin D Female Adaptor
9-Pin D Male
(on VTR)
9-Pin D Male
(on VTR)
Cat 5 Cable
(100 m, or 328 ft)
Cat 5 Cable
(100 m, or 328 ft)
Encore System Controller Frame
8053_39r0
Cat 5 Cable
(100 m, or 328 ft)
RJ-45
Male
RJ-45 Female to
9-Pin D Female Adaptor
RJ-45 Female to
RJ-45 Female Coupler
9-Pin D Male
(on device)
Cat 5 Cable
(100 m, or 328 ft)
RJ-45
Male
RJ-45 Female to
9-Pin D Female Adaptor
RJ-45 Female to
RJ-45 Female Coupler
9-Pin D Male
(on device)
Black
Connectors
Ivory
Connectors
Custom Crossover Cables (174821600)
(20.32 cm, or 8in. max length Cat 5)