Section 2 — Installation
a GP output (contact closure) that can be connected to one of the 14 GP
inputs accessible on the control panel’s D-connector.
Encore and Kalypso panels have 15-pin D-connectors, and SMS panels
have 50-pin D-connectors on the rear of the panel (see
Table 6 on page 51
and Table 7 on page 52).
JSO Configuration
The GP inputs appear in the control panel configuration as additional
control panel configurable inputs. The GP inputs support the following
configuration modes (assignment/selection):
Source Select (latching)/Source Name
When a GP input configured for source select (latching) initiates a contact
closure, the selected source switches to the control panel’s active destina
-
tion. The selected source will remain connected to the active destination
after the GPI contact closure is removed.
Source Select (non-latching)/Source Name
When a GP input configured for source select (non-latching) initiates a
contact closure, the selected source switches to the control panel’s active
destination. The selected source will revert to the previously connected
source (to the active destination) after the GPI contact closure is removed.
Salvo Select/Salvo Name
When a GP input configured for salvo select initiates a contact closure, the
selected salvo shall be executed.
JSO On Updated KAL32UX1, KAL32UX2 Control Panels
KAL32AUX1 and KAL32AUX2 Kalypso style Remote Aux panels can be
used with Encore systems after updating their panel software. The Joystick
Override capabilities described above is also available with these updated
control panels.
JSO On Updated SMS7000 GSC Control Panels
SMS7000 P32 and P48 panels can be equipped with Joystick Override as an
option, by installing a ribbon cable, board and connector assembly. Encore
supports Joystick Override on these panels (up to 24 inputs).