Service manual

Encore — Installation and Service Manual 45
Control Panels
Figure 24. Control Panels on Three Layers of Switches
Note While it is possible to directly connect a control panel to an Encore Control
frame; a direct connection would limit the number of control panels to two
per System Controller. To connect a control panel directly to the Encore
Control frame use a Category 5e Ethernet crossover cable between the LAN
connector on the back of the control panel and the Ethernet connector on the
back of the Encore System Controller frame.
GSC Panel Cabling
GSC Control Panels are controlled by an Encore System Controller with an
GSC ISA mezzanine installed. The GSC ISA mezzanine controls four sets of
Managed Ethernet Switch
Managed Ethernet Switch
To PC-compatibles,
and other devices
8103_00_28_r1
Encore System
Controller Frame
Encore Control Panels
Ethernet Switch
To switches To switches
To panels
(one control panel per port)
To panels
(one control panel per port)
To switches
Ethernet Switch
Ethernet Switch
Encore Control Panels
Ethernet Switch
= Category 5 Ethernet cable
Ethernet Switches: 10/100BaseT
(Note: Hubs will not work in this system)
Control Panels: 10/100BaseT
Encore Control Frame: 100BaseT
(128 maximum per Control Panel Server)
To matrices