Service manual
Encore — Installation and Service Manual 37
Encore System Controller Frame
Figure 17. Control Processor Settings
Serial Interface (SIO) Mezzanine
The Serial Interface (SIO) mezzanine is optional. If purchased with the
System Controller the mezzanine will come installed. If the mezzanine is
purchased separately installation consists of plugging the mezzanine into
the Controller module and securing it with the provided standoff screws.
The SIO ISA BOARD mezzanine provides serial interfaces for eight ports at RS-
422/485. Four of the eight ports will also support RS-232. User adjustments
are available for each port.
SIO ISA Mezzanine Settings
Eight RJ-45 ports are controlled by the SIO ISA mezzanine. The ports are
labelled 0 to 7 on the mezzanine. See Table 3 for port assignments and
signal types. Each port has a Duplex Jumper, which allows you to choose
Half or Full Duplex. The default setting is
Full; if you want to use the Half
setting you must also change the DIP switch setting.
The DIP switch bank has four switches. DIP switches 1 and 2 must be in the
On (default) position to terminate the bus. DIP switches 3 and 4 (Off Full
Duplex is default position) are set to the
On position if the Half position is
selected for the Duplex Jumper.
CAUTION On all mezzanine ports (whether used or unused), DIP switches 1 and 2 must
be in the On position.
BIOS Write Protect Jumper
Place jumper in
Program BIOS position
to program BIOS.
Write Protected
position is default.
Write
Protected
Program
BIOS
JP4
Clear CMOS
Memory
Normal
Place jumper in
Clear CMOS Memory
position to reset
CMOS. Normal
position is default.
JP1
CMOS Jumper
In the On position, a Watchdog
Timeout will cause the module
to reset. In the Off position, a
Watchdog Timeout will cause
a non-maskable interrupt.
Off position is default.
JP5
Off
On
Watchdog Timer Jumper
Upper
Lower
Place jumper in Upper
position to select upper
BIOS bank. Lower
position for lower BIOS
bank is Default.
JP2
BIOS Bank Jumper
8103_00_10R0
Table 3. SIO ISA Ports
Port Number
RS-
232
RS-
422
/485
Mezz Frame
01YesYes
12YesYes
23YesYes
34YesYes
45NoYes
56NoYes
67NoYes
78NoYes