Service manual
Encore — Installation and Service Manual 35
Encore System Controller Frame
48V DC Connections
WARNING Do not apply a 48V DC power source until all 48V DC connections on the
matrices are complete and secure.
The 48V DC connection requires 12 AWG (3.31 mm2) wire and a 3-pin
female terminal block connector. See
Figure 15.
Figure 15. 48V DC Connection
System Controller Frame Module Slots
The Encore System Controller Frame has two slots for System Controller
(SCB) modules, and two slots for power supply modules (see
Figure 3 on
page 25).
Note Modules must be completely seated to operate properly. The fan and LEDs
will come on before the Controller module is fully seated. See the Mainte
-
nance Section (To Insert System Controller Modules on page 73) for instruc-
tions on removing and inserting the Controller module.
System Controller (SCB) Module
The SCB has two standard components, the System Controller module
motherboard and a Control Processor sub-module. Additional SIO and
GSC mezzanines are available, which mount one above the other. The mez
-
zanine mounting order does not affect operation. However, because the
SIO mezzanine has user adjustments, if both are installed it is recom
-
mended to install the SIO mezzanine above the GSC mezzanine
(
Figure 16).
8103_00_18_r0
Tighten screws
to secure wires.
Positive
Negative
3-pin Male
Terminal Block
Connector
3-pin Female
Terminal Block
Connector