Service manual
Encore — Installation and Service Manual 113
Encore Control of Jupiter (Serial)
Jupiter System Settings
Cable Connections
Use the same connectors, adaptors, and cables as shown in Ports 1 to 8 RS-
422/485 on page 57. To create a RJ-45 to 9 pin D adaptor use Table 13 on
page 67, this adaptor is for use with the cables in the Serial Interface Y Cable
Option. The adaptor in Table 12 on page 66 is for use with a ≤4 inch patch
cable.
Table 29. Encore Control Jupiter ESswitch Protocol over Serial Port - Jupiter Settings
Network Description
Board Name VM-3000
Type VM (VM 3000)
Address MAC address of Primary VM3000
Redundant Address MAC address of Secondary VM3000
Serial Protocol
Board VM-3000
Protocol 7/8 ES-W (ES-Switch)
MPK
MPK Device ENCORE
Device Type Serial
Board VM-3000
Port 7
Input Set ENC-INP
Output Set ENC-OUT
Level Set ENC-LVL
Control Panel Sets:
Input Sets:/ENC-INP
Type Serial
Inputs 20
Output Sets:/ENC-OUT
Type Serial
Outputs 10
Level Sets:/ENC-LVL
Type CP3000
Mnemonic JUP-S JUP-A
Level SDV (Default) AES (Default)