Service manual

112 Encore — Installation and Service Manual
Appendix B — Encore System Interface Guide
Encore System Settings
Table 28. Encore Control Jupiter ESswitch Protocol over Serial Port, Encore Settings
Config/Channels
Channel Index 3
Protocol Philips ESswitch
Port 2 NOTE: Any RS-422 port can be used.
Data Bits 8
Stop Bits 1
Baud Rate 38400
Parity Odd
Hand Shake None
Config/Levels
Set Label JUP-S JUP-A
Set Format D G
Config/Phys Matrix/Crosspoint Group
Name JUP_SDV JUP_AES
No. Inputs 20 20
No. Outputs 10 10
No. Segment 1 1
No. Controllers 1 1
Matrix Type Generic Matrix Generic Matrix
Config/Phys Matrix/Controller
Controller No 1 1
Channel 3 3
Address 0 (first level) 1 (second level) NOTE: Encore controls Jupiter
by Index into Jupiter Control
Panel Level Set Tables.
Protocol Philips ESswitch Philips ESswitch
Outputs 10 10
Config/Phys Matrix/Segment
Segment ID A A
Segment Type Blocked Blocked
First Input 1 1
Last Input 20 20
First Output 1 1
Last Output 10 10
Park Input 0 0
No. Vituals 0 0
Config/Logical Matrix
Name SDV AES
Level JUP_S JUP_A
No. Elements 1 1
Element 1 JUP_SDV:A JUP_AES:A