Service manual

Encore — Installation and Service Manual 109
Encore Control of Jupiter (Ethernet)
Encore Control of Jupiter (Ethernet)
Encore System Settings
Table 26. Encore Control of Jupiter over Ethernet using Native Protocol - Encore Settings
Config/Channels
Channel Index 2
Protocol GVG NP
Host IP N/A
Config/Levels
Set Label JUP-S JUP-A
Set Format D G
Config/Phys Matrix/Crosspoint Group
Name JUP_SDV JUP_AES
No. Inputs 20 20 NOTE: The number of inputs
and outputs is arbitrary and
typically a subset of the total.
No. Outputs 10 10
No. Controllers 1 1
No. Segment 1 1
Matrix Type NP Matrix NP Matrix
Config/Phys Matrix/Controller
Controller No. 1 1
Channel 2 2
Address 0 (first level) 1 (second level) NOTE: Encore controls Jupiter
by Index into Jupiter Control
Panel Level Set Tables.
Protocol GVG NP GVG NP
Outputs 10 10
Net Name 192.168.0.10
a
a
Encore controller Net Name is CM-4000 address
192.168.0.10
a
Config/Phys Matrix/Segment
Segment ID A A
Segment Type Blocked Blocked
First Input 1 1
Last Input 20 20
First Output 1 1
Last Output 10 10
Park Input 0 0
No. Virtuals 0 0
Config/Logical Matrix
Name SDV AES
Level JUP_S JUP_A
NO. ELEMENTS 1 1 I
Element 1 JUP_SDV:A JUP_AES:A