Service manual
Encore — Installation and Service Manual 107
Default Network IP Settings (Concerto 64VAA Example)
Default Network IP Settings (Concerto 64VAA Example)
The NetConfig utility program can be used to set IP addresses on Encore
system components. You will need to configure the PC running NetConfig
on the same network as the Encore system components before these com
-
ponents will be recognized by NetConfig.
Note Default IP Addresses are shown, which will need to be changed to add an
Encore system to an existing facility network. If different IP Addresses are
used, be sure the new addresses correspond to each other, as indicated at the
bottom of
Table 24.
Table 24. Encore>Concerto 64VAA Network Configuration Default IP Addresses
Encore System Controllers Encore Controller 1 Encore Controller 2
Master Mirror
System Name SCB-1A SCB-1B
Ethernet1 IP Address 192.168.0.100 192.168.0.101
Ethernet1 Subnet Mask 255.255.255.0 255.255.255.0
Ethernet1 Gateway N/A N/A
Ethernet2 IP Address 192.168.1.1
a
a
Encore Controller 1 Ethernet2 IP Address must match Matrix Controllers 1 & 2 Encore Master Controller IP Address.
192.168.1.2
b
b
Encore Controller 2 Ethernet2 IP Address must match Matrix Controllers 1 & 2 Encore Mirror Controller IP Address.
Ethernet2 Subnet Mask 255.255.255.0 255.255.255.0
Ethernet2 Gateway 192.168.1.1
c
c
Ethernet2 Gateway same as Ethernet2 IP Address for that Encore Controller.
192.168.1.2
c
Concerto Matrix Controllers Matrix Controller 1 Matrix Controller 2
Primary Secondary
Matrix Device Name Concert1 Concert2
Ethernet IP Address 192.168.1.34
d
d
Matrix Controller 1 IP Address must match the Net Name of the Physical Matrix shown in Table 25 on page 108.
192.168.1.35
Ethernet Subnet Mask 255.255.255.0 255.255.255.0
Ethernet Gateway N/A N/A
Encore Master Controller IP 192.168.1.1
a
192.168.1.1
a
Encore Mirror Controller IP 192.168.1.2
b
192.168.1.2
b
PC Running NetConfig
Ethernet IP Address 192.168.0.102
Ethernet Subnet Mask 255.255.255.0
Ethernet Gateway 192.168.0.100
e
e
PC Ethernet Gateway must match Encore Master Controller Ethernet1 IP Address