User`s manual

Serial Communication
SuperDrive 6.10 | 59
(1) PC with SuperDrive software.
(2) DB9 male connector (COM1...COM16).
(3) RS232 serial cable for PC / RS232/RS485 converter connection.
(4) DB9 female connector.
(5) RS232/RS485 converter.
(6) RS232 serial cable for MIW-02/Drive connection.
(7) CEF2 board (optional).
(8) RS232 serial Interface optional board.
(9) EBA optional board (XC4 connector) or EBB (XC5 connector).
(10) Use a terminating resistor when it is the last drive.
EBA board = terminating resistor S3, S3.1=ON and S3.2=ON.
EBB board = terminating resistor S7, S7.1=ON and S7.2=ON.
(11) Use a terminating resistor when it is the last drive.
Terminating resistor S28, S28.1=ON e S28.2=ON.
(12) RS485 Communication Module and Keypad.
(13) Drives.
P.S.: the above figure can be found at directory/folder [Drive]:\WEG\SuperDrive 6.10\Help\.
DRIVE CONFIGURATION OF THE NETWORK
To the network can be connected up to 30 drives. Each drive should have a different address between
1...30. Each drive has a parameter, where this address is selected:
· CFW-05, CFW-07, CFW-08, CFW-09, SSW-05, SCA-05, MVW-01: parameter 308.
· SSW-03, SSW-04: parameter 062.
· SCA-04: parameter 055.
· CTW-04: parameter 084.
RS232/RS485 CONVERTER
For a good system performance, it is recommended to use the following RS232/RS485 converters:
· Opto-isolated RS232/RS485 converter from Advantech Co., Ltd, model Adam-4520
· Opto-isolated RS232/RS485 converter from Black Box Corporation, model IC109A