User`s manual

Serial Communication
SuperDrive 6.10 | 56
310
Serial Bit Rate
1 = 9600 bits/s
311
Data Bits, Parity,
stop bits
7=7bits, even parity,
1 stop bit
312
Serial
Communication
Protocol
0 = WEGBUS
SSW-03
RS232/RS485
62
Drive Address
1
SSW-04
RS232/RS485
62
Drive Address
1
SSW-05
RS232/RS485
308
Drive Address
1
Drive and SuperDrive must use the same settings.
For CTW-04 the general blocking DI (XC1:27) must be with 24 V (General enabled) to allow the
communication to occur.
For SCA-05 P311 and P312 settings are different from the factory default's. The changes made at
these parameters will be valid only after pressing the reset key on the Keypad.
6.2 Protocol
The serial communication protocol is shown below:
Baud Rate
(default) 9600 Bauds (bits/s)
Start Bits
1
Data Bits
7
Parity
Even
Stop Bits
1
6.3 RS232
DESCRIPTION
If running of only one drive is desired, using SuperDrive, and this drive is located at a distance shorter that
10 m from the PC, the connection between the computer and the drive may be performed directly, as
shown in figure below.
This connection if made with RS232 PC/Drive serial cable, supplied in the SuperDrive kit.
If the distance between the PC and the drive is longer than 10 m, see RS485 serial Interface.
CONNECTION
Figure below shows how to connect PC and Drive via RS232 (point-to-point).