User`s manual

Menus
SuperDrive 6.10 | 43
P403 - Motor Rated Frequency
P404 - Motor Rated HP
P405 - Encoder PPR
P406 - Motor Ventilation Type
Basic Application Parameters
The user must define the basic application parameters, which are P100, P101, P133 e P134.
P100 - Acceleration Time
P101 - Deceleration Time
P133 - Minimum Speed Reference
P134 - Maximum Speed Reference
File Name - file name to save the macro.
Save - saves the macro in file.
Search - it allows selecting a macro file.
Print - it prints the macro.
Send - it sends the macro to the drive.
Read the Project - it reads each parameter stored in the project and loads them in the suitable field.
Read the Drive - it reads each parameter from the drive and loads them in the suitable field. The read
parameters are not stored in the project. They are only displayed.
4.5.2 Always Local Command
ACCESS
Menu: Macros + Always Local Command
Shortcut Key: -
FUNCTION
It allows defining the macro for the CFW-09 drive.
The macro parameters can be saved in file. The macro can also be printed.
DESCRIPTION
User can command the drive from an only command origin which commands for speed reference, run/stop
and direction of rotation should be defined previously
The user can visualize the function of each pin of the XC1/XC1A terminal according to the selections. Next
each selected item you can see the content of each parameter which will be sent to the drive when the
macro will be sent.
When Multipeed will be selected in the Speed Reference , the user must fill-in the value of P124 ... P131.
Selections
Options for the Speed Reference:
· Analog Signal from 0 to 10 Vcc - AI1
· Analog Signal from 0 to 10 Vcc - AI2
· Analog Signal from 0 to 20 mA - AI1
· Analog Signal from 0 to 20 mA - AI2
· Analog Signal from 4 to 20 mA - AI1
· Analog Signal from 4 to 20 mA - AI2