User`s manual
Table Of Contents

Menus
SuperDrive 6.10 | 42
4.5 Macros
Basic Application
Always Local Command
Always Remote Command
Multispeed with Commands via Digital Inputs
Local/Remote Command with Selection via HMI
Local Command with Reference via HMI and 3-Wire Start/Stop
4.5.1 Basic Application
ACCESS
Menu: Macros + Basic Application
Shortcut Key: -
FUNCTION
It allows defining the macro for the CFW-09 drive.
The macro parameters may be saved in file. The macro can also be printed.
DESCRIPTION
This application should be used immediately after the routine of the first start-up has been concluded
(loads factory standard parameters) where the drive and the motor data have been defined, including the
type of control. The user defines the max./min. motor speed reference. The user also defines the
acceleration time required for accelerating from the min. frequency up to the max. frequency and the
deceleration time required for decelerating from the max. frequency up to the min. frequency.
Drive Data
The user can see the drive data. However these parameters can not be changed in this window, they can
be displayed only.
These parameters can be changed only by using the offline parameter editor.
Drive Model - CFW-09
P023 - Firmware Version
P296 - Rated Voltage
P295 - Rated Current
Motor Data
The user can see the motor data. However these parameters can not be changed is this window, they can
be displayed only.
These parameters can be changed only by using the offline parameter editor.
P400 - Motor Rated Voltage
P401 - Motor Rated Current
P402 - Motor Rated RPM