User`s manual
Table Of Contents

Menus
SuperDrive 6.10 | 40
textbox.
P.S.: In this mode the zoom cannot be changed.
Print
Press the Print button under the Settings tab to print the current graph screen with the channels data,
trigger date, number of points per channel, and the trigger position.
4.4.11 Error Log
ACCESS
Menu: Online + Error Log
Shortcut Key: -
FUNCTION
This function allows visualizing the last 100 drive errors. Available only for the MVW-01 drive.
DESCRIPTION
With this function, it is possible to retrieve the last 100 errors stored on the drive and see them in a list.
In order to retrieve the errors press the Read Errors button. When the acquisition of the errors is complete,
the data stored on the drive will be presented in a list. These data can be saved to a file by pressing the
Save button.
In order to erase the data for the last errors in the screen press the clear button.
The options for exporting the data to Microsoft Excel and printing the errors list are available.
4.4.12 Identify Drives
ACCESS
Menu: Online + Identify Drives
Shortcut Key: -
FUNCTION
Identifies the drives that are RS232 network or via RS 484 connected. I.e. which drives can communicate
with the SuperDrive.
DESCRIPTION
It is possible to identify the drives automatically or selecting them manually.
SuperDrive reads up to 30 drives that are RS485 network connected.
Automatic Detection
SuperDrive identifies automatically the drives that are network: at the end of the operation, the network