User`s manual
Table Of Contents

Menus
SuperDrive 6.10 | 39
Trigger Value
The trigger value shall be configured with the internal representation of the processor so that the trace
function works properly.
Example: If P550 = 4, set P551 = 4095 to compare the value of P004 with the total DC Link voltage value
(100%). The parameter P004 uses the numerical format Q4.12.
Data acquisition
· The trace function is deactivated by pressing the Inactive button. P.S.: When the Inactive button is
pressed, the previous data stored on the drive is erased.
· The trace configuration and the command to activate the trace function will be sent to the drive when the
Active button is pressed.
Acquiring the trace channels data
The button Acquire trace points and the channel combo boxes will be enabled if the trace status is Trace
complete.
In order to acquire the trace channel data, first selected the desired channels, then change the filename
where the data should be saved (click on Change to change the filename) and finally press the Acquire
trace points button.
It is possible to read data from other channels in different moments and save them in the same file.
Press the Save as button to save the file with a different name. P.S.: the destination filename shall be
different from the source filename to avoid data lost.
Export
It is possible to export the acquisition file data to the Microsoft Excel by pressing the Export button.
GRAPH
The trace information recorded in the file is presented in the left side. The SuperDrive indicates:
· filename;
· address, model, drive firmware version;
· date and time of trigger;
· number of points per channel;
· trigger position;
· parameters of the trace function.
Visualizing channels in the graph
It is possible to choose the channels to be displayed on the graph by clicking on the channel combo boxes
below the horizontal axis scale.
The parameters set in the trace channels are displayed below, where the user can change the scale of
each channel by using the Max and Min textboxes, the line thickness and color for each channel, and see
the parameter value for the channel in the point where the cursor is located (when the Cursor mode is
active).
Horizontal axis scale
The horizontal axis scale can be changed by selecting one of the available options. The Personalized
option allows the user to select a different scale for the graph.
Opening a file with stored data
Click on the Open button under the Settings tab and search for the file you want to display. It is possible to
navigate through the data by using the navigation bar below the graph.
Zoom
Press the Zoom button to activate this function. Click on the graph and drag to select the portion of the
graph you want to apply the zoom. The selected area will be expanded to fit in the whole graph area.
Cursor mode
Click on the Cursor button to activate the cursor mode. In this mode, when you click in any graph point, the
selected point is presented in the bottom part of the graph. The signal values are presented in the Cursor