SuperDrive 6.10 | 35
"P012 - DI6 = 0": when DI6is inactive, the acquisition is started.
"P012 - DI6 = 1": when DI6 is active, the acquisition is started.
"P012 - DI7 = 0": when DI7 is inactive, the acquisition is started.
"P012 - DI7 = 1": when DI7 is active, the acquisition is started.
"P012 - DI8 = 0": when DI8 is inactive, the acquisition is started.
"P012 - DI8 = 1": when DI8 is active, the acquisition is started.
"P012 - DI9 = 0": when DI9 is inactive, the acquisition is started.
"P012 - DI9 = 1": when DI9 is active, the acquisition is started.
"P012 - DI10 = 0": when DI10 is inactive, the acquisition is started.
"P012 - DI10 = 1": when DI10 is active, the acquisition is started.
"<PXXX> > Content": when the content of the indicated parameter is greater than the selected one, the
acquisition is started.
"<PXXX> < Content": when the content of the indicated parameter is less than the selected one, the
acquisition is started.
"<PXXX> = Content": when the content of the indicated parameter is equal to the selected one, the
acquisition is started.
"<PXXX> >= Content": when the content of the indicated parameter is greater then or equal to the selected
one, the acquisition is started.
"<PXXX> <= Content": when the content of the indicated parameter is less than or equal to the selected
one, the acquisition is started.
Parameter/Content: these fields are enabled only when one of the below events are selected.
"<PXXX> > Content"
"<PXXX> < Content"
"<PXXX> = Content"
"<PXXX> >= Content"
"<PXXX> <= Content"
Start Data Acquisition Button: this command is used to start parameter acquisition when set to Manual
Mode.
Trigger Button: this command is used to trigger SuperDrive, i. e., SuperDrive monitors the selected event
until it occurs.
Erase Fields Button: it loads the standard values in the fields.
Ok Button: to exit the window.
Delay in the parameter acquisition with SuperDrive
There is always a delay between the parameter acquisition and the sampling time. If the sampling rate is
set to a value greater than 1 second, the delay in the parameter acquisition is almost imperceptible.
Causes of delay: