SuperDrive 6.10 | 34
Shortcut Key: -
FUNCTION
It allows to acquire up to 4 parameters at the same time.
DESCRIPTION
File Name: file name where the acquired points will be saved.
Example: P9 (full path will be showed on the window)
Drive Address: drive address in the network (01...30).
Parameters Number: number of parameters that will be monitored (01...04).
Parameters: number of each parameter which will be acquired.
Time between points: time between acquisitions.
Milliseconds: range from 200...65535 ms
Seconds: range from 1...65 s
Hour:Minute:Second: range from 00:00:01...23:59:59
Number of Points: number of points to be acquired (read) from drive (1...2000000000)
Trigger Mode: there are 2 modes: manual or event.
In manual mode the user must press the Start button to start the acquisition
In event mode the acquisition is fired after the user has pressed the trigger button and the selected event
has been fired.
Available Events
"Inverter is enabled (RUN)": the acquisition is started, after inverter has been enabled.
"Inverter is READY to be enabled": the acquisition is started, when inverter is ready to be enabled.
"Power supply voltage is too low for the inverter operation (Undervoltage)": when the power supply voltage
is too low for the inverter operation, the acquisition is started.
"P012 - DI1 = 0": when DI1 is inactive, the acquisition is started.
"P012 - DI1 = 1": when DI1 is active, the acquisition is started.
"P012 - DI2 = 0": when DI2 is inactive, the acquisition is started.
"P012 - DI2 = 1": when DI2 is active, the acquisition is started.
"P012 - DI3 = 0": when DI3is inactive, the acquisition is started.
"P012 - DI3 = 1": when DI3 is active, the acquisition is started.
"P012 - DI4 = 0": when DI4is inactive, the acquisition is started.
"P012 - DI4 = 1": when DI4 is active, the acquisition is started.
"P012 - DI5 = 0": when DI5is inactive, the acquisition is started.
"P012 - DI5 = 1": when DI5 is active, the acquisition is started.