SuperDrive 6.10 | 27
DESCRIPTION
Known as upload, the user can visualize the advance of the parameter writing.
Errors that occurred during the writing will be displayed and the end o the writing process.
The user shall select the destination address.
Model, firmware version, and tag of the source drive are automatically presented.
It will be necessary to confirm if SuperDrive must change the configuration of the destination drive on the
project when transferring parameters to a drive with a different address from the source drive. The
information of the connected drive will be stored on the project. However, in case there is already a drive
configured in that address, the configurations of the connected drive will substitute the configurations of the
drive that was previous stored on the project.
It is recommended to write the parameters to drives of the same model and firmware version.
Example:
Source: Address 02, CFW-09 model, firmware version V4.00
Destination: Address 12, CFW-09 model, firmware version V4.00
It is possible to write parameters to different firmware versions in case the drive is from the CFW-09 series.
In order to do that it is necessary to update the parameters to the version of the destination drive.
Currently, the following versions have the automatic updating function: v2.4x, v2.6x, v3.1x, v3.7x and
v4.0x. Any update between these versions can be automatically performed. Versions that were not
mentioned above can be manually updated by using this tool.
4.4.4 Monitor Parameters
ACCESS
Menu: Online + Monitor Parameters
Shortcut Key: -
FUNCTION
It permits online editing of all drive parameters contents.
DESCRIPTION
The online editing consists in showing/changing all parameter contents.
The parameters are showed sequentially on a grid in ascending order. There are two arrows for scrolling
down/up. The grid comprises columns containing a note, the parameter number, function range, factory
setting, user‘s setting, unit and comparison. The only field that can be changed in the grid is the user's
setting.
Visualization
The user‘s field is updated automatically.
Changing