3-36 Encore Multi-port DSU/CSU User GuideÑJuly, 1997
3
NET AIS
Received Alarm
Enabled or Disabled DefaultÑEnabled.
NET Yellow
Received Alarm
Enabled or Disabled DefaultÑEnabled.
AUX Carrier Loss
Alarm
Enabled or Disabled (NA)
AUX Sync Loss
Alarm
Enabled or Disabled (NA)
AUX AIS
Received Alarm
Enabled or Disabled (NA)
AUX Yellow
Received Alarm
Enabled or Disabled (NA)
DATA DTE
Signal Loss
Alarm
Enabled or Disabled DefaultÑEnabled.
BPV Threshold
Alarm
Set A and B in A x
10 ^ B
DefaultÑDisabled. Example: 5 x 10^-4. If the BPVs
exceed the set threshold, the alarm is started.
CRC Threshold
Alarm
Set A and B in A x
10 ^ B
DefaultÑDisabled. Example: 3 x 10^-4. If the CRCs
exceed the set threshold, the alarm is started.
OOF Threshold
Alarm
Set A and B in A x
10 ^ B
(DefaultÑDisabled. Example: 7 x 10^-4. If the
OOFs exceed the set threshold, the alarm is started
Power Supply
Failure Alarm
Enabled or Disabled DefaultÑDisabled.
Controller Card
Missing Alarm
Enabled or Disabled DefaultÑDisabled. The controller
DSU/CSU is
missing
Table 3-13 Menu-7 Alarm I Parameters (Continued)
Parameter Setting Description