User guide
Installation 2-3
2
¥ AUX port interface cable
The cable can have DA-15 male connectors on both ends or a DA-15 male connector
on one end and an RJ-48C male connector on the PBX end.
¥ AC power cord and wall mount -48 VDC adaptor (VX Encore only).
¥ Tray cable
The cable connects the DSU/CSU to DC power, and must be a UL recognized 14
AWG, 3 conductors, copper strand wire, electrical power and control tray cable,
type TC: tray cable, 600 V 90 degree C. An Alpha Wire Company No. 45443 is an
example of a proper DC power cable.
¥ Equipment grounding cable
This cable connects the DSU/CSU to earth ground.
¥ ANSI terminal
Use the ANSI-based VT100-compatible terminal to conÞgure the DSU/CSU.
Equipment Model Numbers
The Digital Link model numbers are listed in Table A-14 on page A-12. Cable and
connector pin-out assignments are listed in Appendix B, Connector Pin Assignments.
Preparing the Required Information
To establish a Telnet connection to a Multi-port Encore DSU/CSU from a remote
terminal and to use SNMP network management, you must specify the DSU/CSU IP
address and IP subnet mask.
In addition, for SNMP network management, you need one to three Network
Management Station (NMS) IP addresses (refer to ConÞguring for SNMP on page 3-28.
Have the work order from service provider containing framing and line code
requirements available.