User guide
A-10 Encore Multi-port DSU/CSU User GuideĆJuly, 1997
A
Comm Port Parameters
Equipment Grounding Conductor
The equipment grounding conductor or cable is connected to ground at the service
equipment.
It should be installed as part of the circuit supplying the system and should not be
smaller in size than the ungrounded branch-circuit supply conductors.
Table A-12 Monitor Jacks.
Item Meaning Description
SND MON Send Monitor The test equipment monitors the signal sent to
the
T1 line. Non-intrusive
SND IN Send In The test equipment injects data into the
T1
line. Intrusive.
RCV MON Receive Monitor The test equipment monitors the signal
received from the
T1 network. Non-intrusive.
Table A-13 Comm Port Parameters
Parameter Option
Baud rate
300, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400
Parity Even, Odd and None
Word length
7 or 8
Comm Port
DCD ON
XOFF Until ON XOFF Until ANY, XOFF Until XON