Service manual
Encore — Configuration Manual 343
Local Router Panel (LRP)
configuration. Field tests should be performed on third-party equip-
ment if maximum loading parameters are required.
• If serial communications are being used, the number of Takes that
can be executed in a single frame is limited by the bandwidth of the
serial channel between the Router Controller and the attached
matrix.
• The number of Takes that can be executed in a single frame is also
limited by the speed with which an attached matrix can respond to,
and acknowledge Take commands.
• If the Router Controller is heavily loaded with Take commands,
determinism of timestamped Takes may be affected, although time
-
stamped Takes do take priority over non-timestamped Takes.
Interlevel Routing
Interlevel routing provides the ability to swap Source Levels when routing
to a Destination. The Interlevel routing panel is operated in the same way
as the Breakaways.
1. Clicking the Inter indicator button toggles it on (indicator shows green),
and off (indicator shows black). When this button is toggled on, clicking
a
Source button will display the Interlevel Routing window.
2. The Interlevel Routing window displays all the Source and Destination
Levels applicable to the routing in two columns. Sources are on the left
and Destinations are on the right. The Levels that are connected to one
another are shown side by side in the columns.
3. Once the Levels have been set, clicking the Route button causes the
Interlevel Routing window to disappear and executes the routing. The
Current State indicator buttons in the Breakaways Area show yellow to
reflect the interlevel route.