Figure 15. Normal Operation Steps
The following steps are involved:
1. The operator presses a Source selector button for a Destination on a
control panel. The Panel button illuminates with a false tally.
2. The Panel sends a button press message to the Panel Server application.
3. The Panel Server interprets the message and sends a Source change
message for that Destination to the Router Control application.
4. The Router Control application interprets the message and sends a
crosspoint change message to the Router Matrix hardware.
5. The Router Matrix changes its crosspoint.
6. The Router Matrix sends a message reporting the new status of that
crosspoint to the Router Control application.
7. The Router Control application sends new Source status information
for that Destination to the Panel Server application.
8. The Panel Server application receives the new status and sends it to the
control panels.
9. All the affected control panels then change their button tally to reflect
the new status of the Destination. The false tally on the initiating control
panel changes to a true tally.
It can take up to four seconds to update all the control panel tally statuses
on a large Encore system. If the requested crosspoint change fails to occur,
Router Control Panel
Panel Client
Router Control
Application
Encore System Controller
Panel Server
Application
Encore System Controller
Panel Client
Router Control Panel
Router Matrix
Frame
Router Client
8531_03r0
Network
Ethernet
Panel button pressed.
1
Button tally
updated on
all panels.
9
2
3
4
Matrix changes
crosspoint.
5
6
8
7