Service manual
270 Encore — Configuration Manual
Section 6 — Control Panel Configuration
Control Panel Partition Configuration
The Multiple Dest Control flag is available for 48B and KSD Control Panels.
When On, the panel can be partitioned. The Bus Assignment mode button
becomes available, and multiple Default Destinations can be defined.
For Encore PMB, and SMS MB8 and MB4 panels this flag is locked On, since
these panels already support multiple Destination control.
If a Control Panel is partitioned with its Monitor Only flag set, only the Desti-
nation controlled by the first bus can be monitored.
Bus Assignment Mode
Clicking on the Bus Assignment button enables Bus Assignment mode. In this
mode, clicking on a button or range of selected buttons brings up a menu
of bus partitions (
Figure 169).
Figure 169. Bus Assignment Modes