Service manual

Encore — Configuration Manual 263
Configuring Encore Control Panels
Shift Button Feature
Introduction
Shifted button functionality is available on all Encore system Control
Panels except ENC-CLNT, SMS-CLNT, SMS-COS, SMS-MCO, and SMS-
SVR. This feature allows a doubling of the number of functions available
on a panel. For example, a BPS32 panel can be configured to access 64
Sources.
Configuration
Shifted button are configured using the Panel Server OUI. Clicking on
Shift Function colors yellow the buttons able to be configured with shifted
functionality (
Figure 137 on page 218). Both a shifted button’s Assignment
and Selection can be changed, using standard configuration methods.
You also will need to add a Shift button to the Control Panel Configuration
in order to access shifted button functions. Once configured, this button
goes high tally when the panel is in the shifted operating mode.
The Shift Latching flag is also available on the Attributes and Flags screen.
When ON, Shifted functions are retained after button presses. When OFF,
the panel returns to the non-shifted state after any button press.
Joystick Override and Shifted Functions
Shifted functions are not applied to Joystick Override inputs.