Service manual

260 Encore — Configuration Manual
Section 6 — Control Panel Configuration
Figure 161. Example of BPS + 48B Panel Group.
1. Log in to the CP Server application.
2. Configure the BPS Master panel:
a. Go to Encore Panels > BPS > Select. Select the BPS panel that will be the
Master panel.
b. Go to Configure BPS Flags > Panel Group Name. This will display the
Panel Groups names list. Select the name of this BPS panel.
c. Configure the individual buttons as desired.
For example, you could configure all 32 assignable buttons for Des-
tination selection. See Figure 161.
d. When finished configuring, select Save to save the configuration
changes.
3. Configure the 48B Expansion panel:
a. Go to Encore Panels > 48B > Select. Select the 48B panel that will be the
Expansion panel.
b. Go to Configure 48B Flags > Panel Group Name. This will display the
“Panel Groups names list.” Select the name of the BPS panel that
will be the Master of the panel group.
c. Configure the individual buttons as desired.
For example, you could configure all of the 48 buttons as Source
Select buttons. In this case, selecting a Source button on the 48B
would execute a Take operation on the controlled Destination of the
BPS. See
Figure 161.
d. When finished configuring, select Save to save the configuration
changes.
As soon as a 48B control panel is configured as the Expansion panel of a
BPS panel, its “Configure Flags” window will no longer be configurable
(except for the Panel Group Name field).
The Expansion panel button configuration screen will now show the fol-
lowing message: “48B Expansion panel of Panel Group BPS<BPS name>.”
“Assignment” and “Selection” menus will have the same functionality as
for the BPS 32 assignable buttons. All the BPS control panel attributes and
flags will apply to the panel group.
Destination Status
Prot
Lvl 1
Chop
Lvl 2 Lvl 3
Lvl 5Lvl 5
Next
Lvl 6
Lvl 4
Prev
All Lvls
Config
Tally
ID
Sources1-48
Destinations 1-32
BPS Master
48B Expansion