Native Protocol Matrix Driver
10. Click on the Config button, then click on Logical Matrix. Configure the
appropriate Levels for the configured physical matrices.
Figure 125. NP Matrix Configuration, Logical Matrix Configure
11. Step 5 through Step 10 can be repeated to create more Cross point
groups and logical matrices. Note that, even if “all level” is chosen for
the Remote System (by specifying the address field as 0 or 255), each of
these logical matrices map on to a single Level on the current router
engine (that is the Local System).
Note A single Encore router can be configured with multiple cross point groups
(physical matrices), each connecting to a different Remote System (that is
multiple SMS 7000 systems).
12. Click on the Config button, then click on the Save button, and then click
on the
Re-Sync Comms, Re-Sync Router and Re-Sync Matrices buttons
respectively. The Remote System must be running and have Ethernet
connectivity for these operations be successful.
13. Click on the Source button and configure the Sources following standard
practices. Enter appropriate values for the ID and Name fields. In the
lower
Matrix Allocation section. Select the appropriate Name and Type.
While selecting the I/O value, the list of remote Source names pops up.
Select the remote Source that has to be associated with the local Source.
The
Copy & Inc button can be used to fill in the rest of the Sources to be
configured if appropriate.
14. Click on the Config button, then click the Destination button. Follow the
same procedure as used above for Sources.