Service manual

Encore — Configuration Manual 185
Output Monitoring
Selecting No Matrix Status Text
To be notified of Matrices going off line and select what status text is dis-
played (NoMatrix or Undef):
1. Log on to the Router Controller OUI and go to the Options screen.
2. Turn ON the Process matrix offline flag.
•Turn ON the Report NoMatrix flag to see status as NoMatrix.
Turn OFF the Report NoMatrix flag to see status as Undef.
Turn OFF the Process matrix offline flag to see the previously taken Source as
the status of Destinations (the previous system behavior).
Figure 111 on
page 180 shows these flags on the Router Controller Options screen.
Output Monitoring
Note Before attempting to configure the Encore for monitoring, monitor wiring and
switch settings for the particular router must be understood and completed.
Please refer to the installation manual for the specific router for more infor
-
mation.
A monitoring system is used to check switcher performance by switching
the output signal of interest to a quality control station. When configured
for output monitoring, the control panel will automatically switch its con
-
trolled Destination to the Monitor output.
See Figure 112.