Service manual

182 Encore — Configuration Manual
Section 5 — Router Configuration
Database Validation
The Router Controller includes a database validity feature.
A Validate DB button indicates the current state of the Router database and
can be used to regenerate the database, which can correct some problems.
This button is available on the Router Controller application Config, Chan
-
nels, Logical Matrix, and Physical Matrix screens.
Sync Matrices
Toggle button. When the indicator is green, the Router
Control application sends its Crosspoint maps to all con
-
trolled matrices. This synchronizes Crosspoint status and
the matrices with the Router Controller.
Salvo Button
When the indicator is green, the Router Controller (on
being booted up) sends the Salvo named in the Salvo field
below this button.
Salvo field
Lists the Salvo to be sent on Router Controller boot up.
Clicking on this window displays the Filer-Fax – this
allows a Salvo to be selected from the Sharer Salvo data
-
base.
No Timeout Error
For Nexus matrix control only. When ON, the master RCE
will not send an error to the Routing clients if there is no
acknowledgement from the primary Nexus controller for
a take from the master RCE. When OFF, the error will be
returned to the routing clients.
Sync Partner
Status
For Nexus matrix control only. When ON the mirror RCE
will sync itself with the status map of the master RCE.
Passive Time Out
For Nexus matrix control only. The time out value the
mirror RCE will wait if there is no acknowledgement
from the primary Nexus controller for a take from the
master RCE.