Service manual
Encore — Configuration Manual 165
Sample Router Configurations
RGB and Key as Two Levels and Two Crosspoint Groups
This example is for two Levels (RGB and Key) with the RGB Level con-
taining 3 elements (R, G and B) and the Key Level containing one element.
The R and G elements are mapped onto one Crosspoint Group. The B
element and the key Level is mapped onto a second Crosspoint Group.
Figure 101. RGB and Key as Two Levels and Two Crosspoint Groups
A Source (or Destination) Level mapped to the RGB logical matrix is con-
figured with a connector in the range 1 to 32. The R element uses the first
Crosspoint Group with the configured crosspoint (1 to 32). The second
element (G) automatically uses the first Crosspoint Group with crosspoints
in the range 33 to 64 (configured crosspoint + 32). The third element (B)
automatically uses the second Crosspoint Group with crosspoints in the
range 1 to 32 (configured crosspoint). The Key logical matrix is on another
Level with a single element. Sources or Destination Levels mapped to the
Key logical matrix uses connectors in the range 33 to 64 on the second Cros
-
spoint Group.
Multi-drop Serial Communications
This example is as described above.
Crosspoint GroupI/O ChannelsLogical Matrices
RGB
32x32 Matrix
Connector ID 1-32
Three Elements
Blocked Format
Key
32x32 Matrix
Connector ID 33-64
One Element
Blocked Format
132
32
64
64
R
G
132
32
64
64
B
K