Service manual

156 Encore — Configuration Manual
Section 5 — Router Configuration
RGB and Key as One Level in One Crosspoint Group
This example is for one Level mapped onto a single Crosspoint Group. This
Level has four elements (R, G, B and Key).
Figure 96. RGB and Key as One Level in One Crosspoint Group
A Source (or Destination) Level mapped to the RGBK logical matrix (on the
RGBK Level) is configured with a connector in the range 1 to 32. Connec
-
tors in the range 33 to 64, 65 to 96 and 97 to 128 are automatically used for
second, third and fourth elements.
Table 15. Configuration for RGB and Key as One Level in One Crosspoint Group
Crosspoint Group
Matrix Controllers
within Crosspoint
Group
Segments within Crosspoint Group Logical Matrix
Name
Max Input
Max Output
Matrix Controllers
Segments
Matrix Controller
I/O Channel
a
a
S = Same for both crosspoint groups; D = Different for each crosspoint group; A = Any channel.
Address
a
Outputs
ID
Input range
Output range
Type & Factor
Unique
Name
Level
Inter levels
Elements
RGBK_Phys 128 128 1 4 1 A A
Xpt
Group
R 1-32 1-32 Block Yes
RGBK RGBK None 4
G 33-64 33-64 Block Yes
B 65-96 65-96 Block Yes
K 97-128 97-128 Block Yes
Crosspoint GroupI/O ChannelsLogical Matrices
132
32
64
64
96
96
128
128
R
G
B
K
RGBK
32x32 Matrix
Connector ID 1-32
Blocked Format
Four Elements