Service manual

Encore — Configuration Manual 155
Sample Router Configurations
RGB and Key as Two Levels in One Crosspoint Group
This example is for two Levels mapped onto the same Crosspoint Group.
The first Level has three elements (R, G and B) and the second Level has one
element (Key).
Figure 95. RGB and Key as Two Levels in One Crosspoint Group
A Source (or Destination) Level mapped to the RGB logical matrix (on the
RGB Level) is configured with a connector in the range 1 to 32. Connectors
in the range 33 to 64 and 65 to 96 are automatically used for second and
third elements. The key logical matrix has a single element and uses con
-
nectors in the range 97 to 128.
Table 14. Configuration for RGB and Key as Two Levels in One Crosspoint Group
Crosspoint Group
Matrix Controllers
within Crosspoint
Group
Segments within Crosspoint Group Logical Matrix
Name
Max Input
Max Output
Matrix Controllers
Segments
Matrix Controller
I/O Channel
a
a
S = Same for both crosspoint groups; D = Different for each crosspoint group; A = Any channel.
Address
a
Outputs
ID
Input range
Output range
Type & Factor
Unique
Name
Level
Inter levels
Elements
RGBK_Phys 128 128 1 4 1 A A
Xpt
Group
R 1-32 1-32 Block Yes
RGB RGB None 3G 33-64 33-64 Block Yes
B 65-96 65-96 Block Yes
K 97-128 97-128 Block Yes Key Key None 1
Crosspoint GroupI/O ChannelsLogical Matrices
RGB
32x32 Matrix
Connector ID 1-32
Blocked Format
Three Elements
Key
32x32 Matrix
Connector ID 97-128
Blocked Format
One Element
132
32
64
64
96
96
128
128
R
G
B
K