ONE STOP MONITORING SOLUTIONS | HYDROLOGY | GEOTECHNICAL | STRUCTURAL | GEODETIC Over 50 years of excellence through ingenuity USERS’ MANUAL WIRELESS ANALOG NODE MODEL EWN-01A/04A Doc. # WI 6002.131 R00 | May 2020 ENCARDIO-RITE ELECTRONICS PVT. LTD. A-7, Industrial Estate, Talkatora Road Lucknow, UP - 226011, India | P: +91 522 2661039-42 | Email: geotech@encardio.com | www.encardio.
Users’ Manual Analog Node Contents 1 QUICK START GUIDE 1 2 SETTING UP WIRELESS ANALOG NODE 2 2.1 Installation 2 2.2 Node Setup 3 2.3 Configuring via the ER Beam Offline App 4 www.encardio.
Users’ Manual 1 Analog Node QUICK START GUIDE Generally, we send devices pre-configured. If your devices are pre-configured by us, please go through the user-friendly procedure to get started with your ER Beam system, which takes only a few minutes to get the process rolling. 1 Power on Gateway and turn on its inbuilt Wi-Fi network. 2 Connect your Android phone to the ER Beam Wi-Fi network. 3 Connect the Android cable to the phone first using the OTG adapter.
Users’ Manual 2 Analog Node SETTING UP WIRELESS ANALOG NODE This section provides information on setting up an Analog Node to work with the offline ER Beam gateway. 2.1 Installation The Nodes can be directly affixed to a flat surface using M6 screws. However, for more sophisticated mounting scenarios, we recommend using the node bracket. The node bracket can be used to easily mount the node on flat surfaces, on pipes using U-bolts or cable-ties, or in other complicated settings.
Users’ Manual 2.2 Analog Node Node Setup 1 Connect the node antenna to the antenna bulkhead. 2 Connect the sensor wires to the node while ensuring that the wires are plugged in correctly. Voltage Output Sensors PWR: +Voltage input to sensor (e.g. +12V) GND: 0 Voltage input to sensor (e.g.
Users’ Manual Analog Node -T: Thermistor SHLD: Shield wire of sensor 3 2.3 Switch off the Node and insert the battery while ensuring the correct polarity. Configuring via the ER Beam Offline App 1 Obtain an Android phone and connect it to the ER_Beam Wi-Fi network. (See the Gateway section to learn about switching on the ER_Beam Wi-Fi network.) 2 Connect the Android smartphone to the Node via an OTG adapter. NOTE: Please make sure the Node is switch off before connecting to your Android phone.
Users’ Manual (i) Analog Node Search for the project, which you have already created once you open your ER app. Select and click the button to download the project and enter in to the project, where the project details would be mentioned.
Users’ Manual Analog Node (ii) Click on “Setup Device” on the menu (at the bottom of screen), the app will show connected node information. (iii) Optional Step: If Wireless Mesh (Relay) function is to be deployed, click on "Wireless Mesh" toggle button to enable.
Users’ Manual Analog Node (v) After clicking ‘Setup Sensor’, sensor setup page will open with the available channels Tap the “Arrow icon” on the respective channel which your sensor is connected to. (vi) Sensor setting can be made as follows: Sensor Code: Desired sensor name. Sensor Type: Select respective sensor type. Parameters: Turn on the parameters as connected to the Node. Excitation time: Set the warm up time required for the sensor.
Users’ Manual (vii) Click Save Settings. The Node will now read the configured sensor. (viii) On next page, you will see the first reading. (ix) Analog Node To get another reading, click on the arrow icon. If the reading is ok, enable the sensor by switching on the android icon (colour changing to blue).
Users’ Manual Analog Node (x) Repeat above steps to configure other sensors connected to the Node. (xi) Once all sensors are configured, click on “Enable Sensor” button. It will take you to next page “Scanning Network” which will scan the wireless signal strength (RSSI) between the Node and Gateway. (xii) After receiving the Network Test information, if you need to, you can perform another network test by pressing the button located at the lower right corner.
Users’ Manual (xiii) (xiv) Analog Node Next, click “Start Monitoring” button then the app will prompt, “Device commissioned”. Click OK. Press the Project Sync button at lower right area to send all the configuration information back to the gateway.
Users’ Manual Analog Node (xv) If you would like to get the Node to immediately send a reading to the Gateway, press the “SYS TEST” button on the device’s printed circuit board as shown below. (xvi) For commissioning of additional Nodes, repeat the above steps. (xvii) Now proceed to the Gateway software dashboard on your Laptop and click on your project. Now you will be able to observe your commissioned devices under “Device Summary” Section.