INSTALLING THE 895 EXTENDED ETHERNET UNITS
The Enable-IT 895 Extended Ethernet Units have a distance restriction of 1,970ft or
600m over 1-pair of Category 2 up to Category 5e / CAT6 wiring from device extension
to device extension. Therefore quick, simple site surveys and installation planning are
highly recommended.
This chapter describes the recommended installation process for the Enable-IT 895
Extended Ethernet Unit. It covers the following topics:
Site Plan Installation Design Considerations
Unpacking the Enable-IT 895 Extended Ethernet Units
Performing the On-Site Installation
Site Plan - Installation Design Considerations
The planning process should involve a site walkthrough and discovery survey. Electrical
Cable measurement tools are the most reliable method to determine the longest run of
hidden wiring. Estimate the best locations to position the Broadband Concentrators to
adequately reach desired connectivity on each floor. Document your findings to use in
designing a network topology to support the Ethernet Switches and backbone
connectivity. Key points to remember in the Site Survey.
Total distance limitation of 1,970ft over CAT2 up to CAT5e/CAT6 wiring from end
to end.
1 Pair CAT-2 Telco wiring .30 Gage or better cabling is required for transmission.
We highly recommend a quick test to ensure the working order of you 895
units. To do this, please use one of the telephone patch cords provided
and attach each end to the LINE port on the 895 units. Power up until you
see a Green SYNC light on each unit. This confirms proper operation of the
units.
Note: The innermost pins (2 & 3) are used for transport for both voice and data. The
895 will auto detect the polarity of the pins if flipped on the remote side and correct for
communications. If using twisted pair cabling such as CAT5e, cut the RJ-45 male head
of each end of the CAT5e segment and crimp on a RJ-11 head to one pair of the wiring
using the inside RJ-11 pins (2 & 3) and insert into the HPNA port of the 895 unit.
You can use PoE on the other free pairs of the same CAT5e cabling.