User`s manual

December 2003
3-46 Programming Site Data
Entering Averaging Parameters
The AVeRaGe sub-option enables you to select the response time.
The TransPort enables you to select a response time for the unit to
respond to a step change in flow rate. In general, the faster the
response time, the less steady the reading will appear. Normally,
use statistics for the best results. Statistics increases the averaging
under steady flow conditions, but allows for a rapid response to
step changes in flow rate.
It is important to note that response times are approximate, since
response time can be affected by such factors as pipe geometry.
To enter the AVeRaGe sub-option, press [F2]. The indicator box
indicates you are at the beginning of the AVeRaGe sub-option.
Use the [] [] to view all the selections, then use the
appropriate feature key to respond.
Selecting the Decimal Digits
This sub-option enables you to select the digits to the right of the
decimal for volumetric, total, power, and energy flow rate.
To enter the DIGIT sub-option, press [F3]. The indicator box
indicates that you are at the beginning of the DIGIT sub-option.
Use the appropriate feature key to choose a number from 0 to 3
for the desired digits for the following:
Volumetric
Totals
Power
Energy
Initializing Setup Parameters
This sub-option lets you set all the setup parameters to their
default values. To initialize setup parameters, press [F4]. Press
[F1] to cancel or [F2] to initialize. The TransPort re-initializes the
setup parameters when you exit the Program Menu.