User`s manual

Programming Site Data 3-45
December 2003
Entering Signal Limits (cont.)
13. Setting the Transmitter Sample Size
Consult GE Panametrics before performing this step.
The transmitter sample size is the number of pulses each
transducer (upstream and downstream) emits. This number is set
to 8 by default.
Use the appropriate feature key to respond.
14. Entering the Number of Errors Allowed
The TransPort needs to know the number of errors it can record
before it displays an error message. To enter a value (over a range
from 0 to 16, with a default of 8), use the numeric keys and press
[ENT].
15. Entering the Minimum and Maximum Peak % Limits
Users can select the minimum and maximum percent of peak
(step 11) that the TransPort can use to measure transit time, over a
range of -100 to +100. Use the numeric keys to enter a value and
press [ENT].