User`s manual
Programming Site Data 3-19
December 2003
Entering Parameters for Clamp-On Transducers
(cont.)
8C.Entering the Fluid Type
The next prompt asks you to enter the fluid type. You may choose
one of the following:
• water
• water, glycol mixture (for energy option only)
• oil (lube or crude)
• methanol
• ethanol
• LN
2
• freon
• other
If you have enabled the tracking windows, you may choose the
following:
• Water, 0-100°C
• Water, 0-260°C
• Oil
• Other — Enter sound speed limits
Use the appropriate feature key to make a choice. Depending on
the fluid type you choose, the TransPort may ask you for
additional information (for example, soundspeed limits for
“Other”.)
Note: If you have selected the energy option, only three fluid
types will appear on the menu: water, mixed (water, glycol
mixture) and other.