A-8 Entering Special Transducer Pipe Parameters
Entering Parameters for Clamp-On Transducers
(cont.)
10C. Entering Pipe Lining
Clamp-on transducers can be used on pipe with a variety of pipe
linings; however, the options list only a few types. If your lining
is not among the options, select “OTHER” and enter the sound
speed of your lining material from the tables in Sound Speeds and
Pipe Size Data.
If your pipe does not have a lining, press [F1] to respond no and
the TransPort proceeds to the next prompt.
If your pipe does have a lining, use the following steps to enter
lining information:
1. Press [F2].
2. Use the appropriate feature key to choose the lining material.
Note: If you choose “OTHER,” the TransPort then asks you to
enter the lining sound speed. If you do not know the lining
sound speed, Sound Speeds and Pipe Size Data lists some
standard materials and their corresponding sound speeds.
3. Use the numeric keys to enter the lining thickness. Press
[ENT].