User`s manual

Specifications 11-3
December 2003
Electrical
Meter
Operating Power: 6 W, maximum.
Fuses: One 250 mA, 32V.
Two 1 A, 125V, Slo-Blo.
Internal Batteries
Size: 4 C NiCad high-energy rechargeable batteries.
Battery Life: 8-10 hours of continuous operation is typical.
The battery life will be reduced if you use the
4-20 mA output and/or loop powered
temperature inputs, or the printer output.
Recharge Time: 16-20 hours using the internal charger.
External DC Power/Charger
Voltage: 10 VDC to 28 VDC
Power: 4 Watts maximum
External AC Charger/Supply Module:
Input: 100/120 VAC or 200/260 VAC, 50/60 Hz,
5 W, maximum
Output: 12 VDC unregulated
Size/Weight
Size: 12.7 mm × 22.9 mm × 5.8 cm
(5 × 9 × 2.3 inches)
Weight: 1.0 kg (2.2 lb)
Environmental
Operating
Temperature: -10 to 50°C (14 to 122° F)
Storage
Temperature: -10 to 50 °C (-4 to 122° F)
Note: To ensure maximum battery life storage, do not exceed
35 °C (95° F) for long periods.